Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
JCI Insight ; 8(8)2023 04 24.
Artigo em Inglês | MEDLINE | ID: mdl-36853828

RESUMO

The need for advances in the management/treatment options for ischemic stroke patients requires that upcoming preclinical research uses animals with more human-like brain characteristics. The porcine brain is considered appropriate, although the presence of the rete mirabile (RM) prevents direct catheterization of the intracranial arteries to produce focal cerebral ischemia. To develop a reproducible minimally invasive porcine stroke model, a guide catheter and guide wire were introduced through the femoral artery until reaching the left RM. Using the pressure cooker technique, Squid-12 embolization material was deposited to fill, overflow, and occlude the left RM, the left internal carotid artery, and left circle of Willis wing up to the origins of the middle cerebral arteries (MCAs), mimicking the occlusion produced in the filament model in rodents. Longitudinal multimodal cerebral MRI was conducted to assess the brain damage and cerebral blood supply. The technique we describe here occluded up to the origins of the MCAs in 7 of 8 swine, inducing early damage 90 minutes after occlusion that later evolved to a large cerebral infarction and producing no mortality during the intervention. This minimally invasive ischemic stroke model in swine produced reproducible infarcts and shows translational features common to human stroke.


Assuntos
Isquemia Encefálica , AVC Isquêmico , Acidente Vascular Cerebral , Humanos , Animais , Suínos , Isquemia Encefálica/diagnóstico por imagem , Acidente Vascular Cerebral/diagnóstico por imagem , Encéfalo/diagnóstico por imagem , Artérias
2.
Paediatr Respir Rev ; 35: 61-63, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32690356

RESUMO

There are significant logistical challenges to providing respiratory support devices, beyond simple oxygen flow, when centres run out of supplies or do not have these devices at all, such as in low resource settings. At the peak of the COVID-19 crisis, it was extremely difficult to import medical equipment and supplies, because most countries prohibited the medical industry from selling outside of their own countries. As a consequence, engineering teams worldwide volunteered to develop emergency devices, and medical experts in mechanical ventilation helped to guide the design and evaluation of prototypes. Although regulations vary among countries, given the emergency situation, some Regulatory Agencies facilitated expedited procedures. However, laboratory and animal model testing are crucial to minimize the potential risk for patients when treated with a device that may worsen clinical outcome if poorly designed or misused.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas/instrumentação , Infecções por Coronavirus/terapia , Legislação de Dispositivos Médicos , Pneumonia Viral/terapia , Síndrome do Desconforto Respiratório/terapia , Insuficiência Respiratória/terapia , Ventiladores Mecânicos/provisão & distribuição , Betacoronavirus , COVID-19 , Aprovação de Equipamentos , Reeducação Profissional , Desenho de Equipamento , Equipamentos e Provisões/provisão & distribuição , Humanos , Ventilação não Invasiva/instrumentação , Pandemias , Admissão e Escalonamento de Pessoal , Respiração Artificial/instrumentação , SARS-CoV-2 , Espanha
3.
Vet Clin North Am Exot Anim Pract ; 18(3): 527-39, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26095318

RESUMO

Cloacoscopy and cystoscopy are simple, noninvasive to minimally invasive techniques that provide excellent visualization, and result in fast recovery. General or intrathecal anesthesia is sufficient. They can be performed in free-ranging turtles under field conditions. Cloacoscopic gender identification of external genitalia is not reliable because of the high degree of misinterpretation between phallus and clitoris, especially in juveniles. However, saline-infusion or air insufflation cystoscopy through the urinary bladder (or accessory vesicles/bladders) is often effective for the visualization of gonads and to identify the sex. Visualization of gonads is feasible through the urinary bladder or accessory vesicle wall in many species.


Assuntos
Cloaca/anatomia & histologia , Cistoscopia/veterinária , Análise para Determinação do Sexo/veterinária , Tartarugas/anatomia & histologia , Animais , Cistoscopia/métodos , Feminino , Masculino , Análise para Determinação do Sexo/métodos , Bexiga Urinária/anatomia & histologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...